Title

12 WAS Pump Start Up

Two 10 HP, variable speed, non-clog type pumps each with a capacity of 3750 gpm make up the WAS Pumping System. The Lead/Lag status of the pumps is manually changed by the operator each month.

SOP Identification Number
SOP Identification Number:
1205 - WAS Pump Start Up
Purpose and scope
Purpose and scope:

The WAS Pumps serve two main functions:

  • Pump the excess biomass from the Secondary Clarifiers to the Solids Handling facilities for further processing (normal operation)
  • Drain the Secondary Clarifiers
Definitions
Definitions:
  • WAS: Waste Activated Sludge
Health & Safety Warnings
Health & Safety Warnings:

Watch for open tanks, vaults and channels.  If working on or near equipment, watch for rotating parts. 

Cautions
Cautions:
  • Verify that suction valve(s) are open. Verify that discharge valve(s) are open during normal operation.
  •  Verify that suction valve(s) are open. Verify that drain valve(s) are open when draining clarifiers.
Potential Interferences
Potential Interferences:

Inaccurate pump speed setting at the VFD.

Personnel Qualifications
Personnel Qualifications:

Operator 1, knowledge of secondary treatment process and equipment controls.

Quality Control/Quality Assurance Activities for the Procedure
Quality Control/Quality Assurance Activities for the Procedure:
  • Record activity to log book.
  • Compare flow rates with the SCADA target rate.
Procedure
Procedure:

1.     Check Valve Status :

a.     Locate the Suction Valve {tag nos. 1205VLV2100 & 1205VLV2200}.  Open the valve if it is not already open.

b.     Locate the Secondary Drain Valve {tag nos. 1205VLV2679N & 1205VLV2679O} .  Close the valve if it is not already closed.

c.     Locate the Discharge Drain Valve {tag nos. 1205VLV2672 & 1205VLV2672A}.  Close the valve if it is not already closed.

d.     Locate the Discharge Isolation Valve {tag nos. 1205VLV2100A & 1205VLV2200A}.  Open the valve if is it not already open.

e.     Locate the Sampler Tube, which is located on the discharge piping.  Open the valve for the pump that is to be put into service.  Close the valve for the pump that will not be in service.

2.     Prepare Pumps for Start Up at Control Panel:

a.     Locate the stantion with the local and Lockout Switch {tag nos. 1205HS2100A & 1205HS2200A} and HOA Switch {tag nos. 1205HS2100 & 1205HS2200}.  Verify that the Lockout Switch {tag nos. 1205HS2100A & 1205HS2200A} is in the ON position and the HOA Switch {tag nos. 1205HS2100 & 1205HS2200} is in the AUTO position.

b.     At the Control Panel, locate the Main Breaker {tag nos. 1205FBK2100 & 1205FBK2200}.  Flip the switch to the ON position.

c.     At the Control Panel, locate the VFD Breaker {tag nos. 1205FBK2100A & 1205FBK2200A}.  Flip the switch to the ON position.

d.     At the Control Panel, locate the HOA Switch {tag nos. 1205HS2100 & 1205HS2200}.  Flip the switch to the AUTO position.

e.     Verify that the Pump On Indicator Light {tag nos. 1205YL2100 & 1205YL2200} is on.

3.     Start Up Pumps from SCADA (Automatic Operation):

a.     At the SCADA Workstation, verify that the pumps are in AUTO mode.

b.     Verify the lead/lag status of the pumps.

c.     Enter the target wasting rate.

4.     Start Up Pumps from SCADA (Manual Operation):

a.     Locate the VFD HMI {tag nos. 1205HMI2100 & 1205HMI2200}.

b.     Start the pump and adjust the pump speed.

c.     Locate the Pump Run Indicator Light {tag nos. 1205YL2100A & 1205YL2200A} and verify that it is ON.

5.     Observe WAS Pump Operation:

a.     Listen for excessive noise or vibration.

b.     Check for oil or process fluid leaks.

6.     Record Data to Operator’s Log BookRecord WAS Pump Activities to the log book with other entries for the day.  Include the following in the entry:

·         Operator(s) that performed the WAS Pump Start Up SOP.

·         Note condition of equipment, piping, valves, etc.

·         Note any unusual conditions with flows, levels, odors or other process issues.

·         Note any damage, wear, or required maintenance on equipment.

Data & Records Management, Calculations, Forms, Reports
Data & Records Management, Calculations, Forms, Reports:
  • Update log book.
  • Update maintenance records (if applicable).
  • Report any maintenance or attention that is required.
Limits/Criteria for Data/Results
Limits/Criteria for Data/Results:
  • WAS is pumped from the Secondary Clarifiers to the Solids Handling processes (normal operation).
  • The Secondary Clarifiers are drained.
Equipment
Equipment:

EQUIPMENT NAME

TAG NUMBER

WAS Transfer Pump No. 1

1205PMP2100

WAS Transfer Pump No. 1 Motor

1205MTR2100

WAS Transfer Pump No. 1 VFD

1205VFD2100

WAS Transfer Pump No. 1

1205PMP2100

WAS Transfer Pump No. 1 Motor

1205MTR2100

WAS Transfer Pump No. 1 VFD

1205VFD2100

WAS Transfer Pump No. 1 – Suction Valve

1205VLV2100

WAS Transfer Pump No. 1 - Discharge Valve

1205VLV2100A

WAS Transfer Pump No. 1 – Discharge Header Drainage Valve

1205VLV2672

WAS Transfer Pump No.1 – Secondary Clarifier Drain

1205VLV2697N

WAS Transfer Pump No. 1- Local HOA Switch

1205HS2100

WAS Transfer Pump No. 1 - Local Start Switch

1205HS2100A

WAS Transfer Pump No. 1- Main Breaker

1205FBK2100

WAS Transfer Pump No. 1- VFD Breaker

1205FBK2100A

WAS Transfer Pump No. 1- Bucket

1205BKT2100

WAS Transfer Pump No. 1- HMI Interface

1205HMI2100

WAS Transfer Pump No. 1- Indicator Light

1205YL2100

WAS Transfer Pump No. 1- Run Light

1205YL2100A

WAS Transfer Pump No. 1- Sampler Tube

 

WAS Transfer Pump No. 2

1205PMP2200

WAS Transfer Pump No. 2 Motor

1205MTR2200

WAS Transfer Pump No. 2 VFD

1205VFD2200

WAS Transfer Pump No. 2 – Suction Valve

1205VLV2200

WAS Transfer Pump No. 2 - Discharge Valve

1205VLV2200A

WAS Transfer Pump No. 2 – Discharge Header Drainage Valve

1205VLV2672A

WAS Transfer Pump No.2 – Secondary Clarifier Drain

1205VLV2697O

WAS Transfer Pump No. 2- Local HOA Switch

1205HS2200

WAS Transfer Pump No. 2 - Local Start Switch

1205HS2200A

WAS Transfer Pump No. 2- Main Breaker

1205FBK2200

WAS Transfer Pump No. 2- VFD Breaker

1205FBK2200A

WAS Transfer Pump No. 2- Bucket

1205BKT2200

WAS Transfer Pump No. 2- HMI Interface

1205HMI2200

WAS Transfer Pump No. 2- Indicator Light

1205YL2200

WAS Transfer Pump No. 2- Run Light

1205YL2200A

WAS Transfer Pump No. 2 - Sampler Tube